Type
AESV / AESU Horizontal Foot Mounting / Vertical Mounting Low Voltage Squirrel Cage Induction Motors IEC Standard size TECO has exclusive type for each area Output 0.55~315kw Pole (Speed) 2~ 8 Voltage 380V, 400V, 415V or others Frequency (Hz) 50,60 Frame Size 80M~355L Protection Enclosure IP 55 Efficiency IE1,IE2,IE3 Design Standards: IEC, BS, NEMA, JEC Environment: non-hazardous, shadow
AECD TEAAC, Squirrel Cage Output 350~1000HP (260 ~750 KW) Pole (Speed) 2~ 10 Voltage 380V, 415V, 460V, 660V Frequency (Hz) 50 Frame Size 400A~560C Protection Enclosure IP 44 Design Standards: IEC, BS, NEMA, JEC Environment: non-hazardous, shadow
AEEA / AEVA /AEEACF / AEEAFB / AEEAHD TEFC T-Frame Design B or C Output 3/4 ~800HP Pole (Speed) 2 ~ 12 Voltage 230/460V, 460V, 575V Frequency (Hz) 60 Frame Size 143T~449T 5007 ~ 6810 Protection Enclosure IP 44 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator insulation: Class F Insulation, B rise at SF 1.15
AEEAJM / AEEAJP TEFC T-Frame Design B Output 3/4 ~75 HP Pole (Speed) 2 ~ 6 Voltage 230/460V Frequency (Hz) 60 Frame Size 143JM ~ 326JM 143JP ~ 365JP Protection Enclosure IP 44 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator insulation: Class F Insulation, 90¢J rise at SF 1.15
AEEAGD Low Voltage, TEFC NEMA Design C, Code G Output 200 ~ 500 HP Pole (Speed) 4 ~ 8 Voltage 460V, 575V Frequency (Hz) 60 Frame Size 143T~449T 5007C ~ 5808C Protection Enclosure IP 55 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous, shadow Stator insulation: Class F Insulation, B rise at SF 1.15 Drive Method: Belt service
AEEB TEFC T-Frame Design N Output 0.18 ~ 185 KW Pole (Speed) 2 ~ 8 Voltage 380V, 400V, 415V, 440V Frequency (Hz) 50 Frame Size 63~315MC Protection Enclosure IP 44 Design Standards: BS, AS Environment: non-hazardous Stator insulation: Class F Insulation, 80¢J rise at SF 1.0
AEED / AEEDWA Output 75~250HP (55KW~185kw) Pole (Speed) 2 ~ 8 Voltage 200V, 220V, 346V, 380V, 400V, 415V, 440V Frequency (Hz) 50, 60 Frame Size 280SA~315MC Protection Enclosure IP 44 Design Standards: IEC, JEC, CNS Environment: non-hazardous, outdoor service for AEEDWA. Stator insulation: Class F Insulation
AEEF / AEVF IEC Standard size Output 1/4~270 HP Pole (Speed) 2 ~ 8 Voltage below 600V Frequency (Hz) 50, 60 Frame Size 63 ~ 315M Protection Enclosure IP 54 Design Standards: IEC, CNS Environment: non-hazardous Stator insulation: Class E, B, F Insulation
AEEM Class A temperature rise. Output 1/4 ~ 5 HP Pole (Speed) 4, 6 Voltage below 600V Frequency (Hz) 50, 60 Frame Size 71 ~ 132S Protection Enclosure: IP 44 Design Standards: IEC, CNS Environment: non-hazardous Stator insulation: Class E, B, F Insulation
AEVBYH High Temperature Resistant 3-Phase Induction Motors Low Voltage Squirrel Cage TEFC, Class H Insulation, BS, AS Design N Output 0.75 ~ 185 KW (1 ~ 250 HP) Pole (Speed) 2 ~ 8 Voltage 380V, 400V, 415V, 440V Frequency (Hz) 50, 60 Frame Size 80 ~ 315MB Protection Enclosure: IP 54, (IP 55 Option)
ASFA ODP Standard Efficiency Motors NEMA Design B Output 3/4~800HP Pole (Speed) 2 ~ 12 Voltage 230/460V, 460V, 575V Frequency (Hz) 60 Frame Size 143T~449TS 5007 ~ 6808 Enclosure IP 22 Open, Drip-Proof Protection Enclosure: Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator insulation: Class F Insulation, 90¢Jrise at SF 1.15 Full Voltage or Wye-Delta srating Oversized Ball/Roller Bearings
ASFB Horizontal Foot Mounting BS, AS Design N Output (HP) 7.5 ~ 250 kw Pole (Speed) 2 ~ 8 Voltage 380V, 400V, 415V, 440V Frequency (Hz) 50, 60 Frame Size 160M ~ 315MC Protection Enclosure IP 22 Open, Drip-Proof Design Standards: BS, AS Environment: non-hazardous, indoor Stator insulation: Class B Insulation, 80¢J at SF 1.0; Class F.